> ## Documentation Index
> Fetch the complete documentation index at: https://dragonwingdocs.qualcomm.com/llms.txt
> Use this file to discover all available pages before exploring further.

# Platform support for thermal management

## Supported Platforms

The following platforms are supported for thermal management on Qualcomm Linux:

* **QCS6490/QCS5430**
* **IQ-9075**
* **IQ-8275**
* **IQ-615**
* **IQ-X7181/IQ-X5121**
* **CQ2390**

***

> [tab] QCS6490/QCS5430
>
> **Table: Temperature for hardware and software throttling for QCS6490/QCS5430**
>
> | Mitigation Actions | Details |
> | - | - |
> | Software throttling | • NSP: 100°C - Frequency throttling  • GPU: 105°C - Frequency throttling |
> | Hardware throttling | • CPU: 95°C/105°C - Frequency throttling (105°C for 300-AA parts only)  • NSP: 102°C - Frequency throttling |
> | BCL | [Learn more](https://dragonwingdocs.qualcomm.com/archives/2.0/System/Power/BCL.md) |
> | ThermalD | [Learn more](https://dragonwingdocs.qualcomm.com/archives/2.0/System/Power/thermalD.md) |
> | Software shutdown | 118°C - Device shutdown |
> | Hardware shutdown | 120°C - Device shutdown |
>
> **Table: Available CPU cooling devices to user space for QCS6490/QCS5430**
>
> | **Cooling devices** | **Description** |
> | - | - |
> | `cpufreq-cpu<x>` | Cooling devices that are used to limit the maximum operating frequency of the CPU to control CPU temperature. <ul><li>`X` – Cluster CPU number</li><li>`cpufreq-cpu0` – Silver cluster</li><li>`cpufreq-cpu4` – Gold cluster</li><li>`cpufreq-cpu7` – Prime cluster</li></ul> |
> | `devfreq-3d00000.gpu` | Cooling devices that are used to limit the maximum operating frequency of the GPU to control GPU temperature. |

> [tab] IQ-9075
>
> See lemans.dtsi to review the kernel thermal rules.
>
> **Table: Temperature for hardware and software throttling for IQ-9075**
>
> | Mitigation Actions | Details |
> | - | - |
> | Software throttling | • NSP: 105°C - Frequency throttling  • GPU: 105°C - Frequency throttling |
> | Hardware throttling | • CPU: 110°C - Frequency throttling  • NSP: 110°C - Frequency throttling |
> | BCL | Not applicable |
> | ThermalD | [Learn more](https://dragonwingdocs.qualcomm.com/archives/2.0/System/Power/thermalD.md) |
> | Software shutdown | 118°C - Device shutdown |
> | Hardware shutdown | 120°C - Device shutdown |
>
> **Table: Available CPU cooling devices to user space for IQ-9075**
>
> | **Cooling devices** | **Description** |
> | - | - |
> | `cpufreq-cpu\<x\>` | Cooling devices that are used to limit the maximum operating frequency of the CPU to control CPU temperature. <ul><li>`X` – CPU number varies from 1 to 7</li><li>`X` – Cluster CPU number</li><li>`cpufreq-cpu0` – Cluster0</li><li>`cpufreq-cpu4` – Cluster1</li></ul> |
> | `rproc\_cdsp:cdsp\_sw` | Cooling devices that are used to limit the maximum operating frequency of the NPU to control NPU temperature. |
> | `devfreq-3d00000.gpu` | Cooling devices that are used to limit the maximum operating frequency of the GPU to control GPU temperature. |

> [tab] IQ-8275
>
> See monaco.dtsi to review the kernel thermal rules.
>
> **Table: Temperature for hardware and software throttling for IQ-8275**
>
> | Mitigation Actions | Details |
> | - | - |
> | Software throttling | • NSP: 105°C - Frequency throttling  • GPU: 105°C - Frequency throttling |
> | Hardware throttling | • CPU: 110°C - Frequency throttling  • NSP: 110°C - Frequency throttling |
> | BCL | Not applicable |
> | ThermalD | [Learn more](https://dragonwingdocs.qualcomm.com/archives/2.0/System/Power/thermalD.md) |
> | Software shutdown | 118°C - Device shutdown |
> | Hardware shutdown | 120°C - Device shutdown |
>
> **Note:** The thermal rules for IQ-8275 will be enabled in the future release.
>
> **Table: Available CPU cooling devices to user space for IQ-8275**
>
> | **Cooling devices** | **Description** |
> | - | - |
> | `cpufreq-cpu\<x\>` | Cooling devices that are used to limit the maximum operating frequency of the CPU to control CPU temperature. <ul><li>`X` – CPU number varies from 0 to 7</li><li>`X` – Cluster CPU number</li><li>`cpufreq-cpu0` – Gold cluster</li><li>`cpufreq-cpu2` – Prime cluster</li><li>`cpufreq-cpu4` – Silver cluster</li></ul> |
> | `rproc\_cdsp:cdsp\_sw` | Cooling devices that are used to limit the maximum operating frequency of the NPU to control NPU temperature. |
> | `devfreq-3d00000.gpu` | Cooling devices that are used to limit the maximum operating frequency of the GPU to control GPU temperature. |

> [tab] IQ-615
>
> See talos.dtsi to review the kernel thermal rules.
>
> **Table: Temperature for hardware and software throttling for IQ-615**
>
> | Mitigation Actions | Details |
> | - | - |
> | Software throttling | • NSP: 105°C - Frequency throttling  • GPU: 105°C - Frequency throttling |
> | Hardware throttling | • CPU: 105°C - Frequency throttling  • NSP: 102°C - Frequency throttling |
> | BCL | Not applicable |
> | ThermalD | [Learn more](https://dragonwingdocs.qualcomm.com/archives/2.0/System/Power/thermalD.md) |
> | Software shutdown | 115°C - Device shutdown |
> | Hardware shutdown | 120°C - Device shutdown |
>
> **Note:** The core idle injection functionality will be enabled in future release.
>
> **Table: Available CPU cooling devices to user space for IQ-615**
>
> | **Cooling devices** | **Description** |
> | - | - |
> | `cpufreq-cpu\<x\>` | Cooling devices that are used to limit the maximum operating frequency of the CPU to control CPU temperature. <ul><li>`X` – CPU number varies from 0 to 5</li><li>`X` – Cluster CPU number</li><li>`cpufreq-cpu0` – Silver cluster</li><li>`cpufreq-cpu4` – Gold cluster</li></ul> |
> | `rproc\_cdsp:cdsp\_sw` | Cooling devices that are used to limit the maximum operating frequency of the NPU to control NPU temperature. |
> | `devfreq-5000000.gpu` | Cooling devices that are used to limit the maximum operating frequency of the GPU to control GPU temperature. |

> [tab] IQ-X7181/IQ-X5121
>
> See hamoa.dtsi to review the kernel thermal rules.
>
> **Table: Temperature for hardware and software throttling for IQ-X7181/IQ-X5121**
>
> | Mitigation Actions | Details |
> | - | - |
> | Software throttling | GPU: 105°C - Frequency throttling |
> | Hardware throttling | • CPU: IL: 112°C, OL: 105°C - Frequency throttling  • NSP: IL: 105°C - Frequency throttling |
> | BCL | |
> | ThermalD | [Learn more](https://dragonwingdocs.qualcomm.com/archives/2.0/System/Power/thermalD.md) |
> | Software shutdown | 115°C - Device shutdown |
> | Hardware shutdown | 120°C - Device shutdown |
>
> **Table: Available CPU cooling devices to user space for IQ-X7181/IQ-X5121**
>
> | **Cooling devices** | **Description** |
> | - | - |
> | `cpufreq-cpu\<x\>` | Cooling devices that are used to limit the maximum operating frequency of the CPU to control CPU temperature. <ul><li>`X` – Cluster CPU number</li><li>`cpufreq-cpu0` – Cluster0</li><li>`cpufreq-cpu4` – Cluster1</li><li>`cpufreq-cpu8` – Cluster2</li></ul> |
> | `devfreq-3d00000.gpu` | Cooling devices that are used to limit the maximum operating frequency of the GPU to control GPU temperature. |

> [tab] CQ2390
>
> See shikra.dtsi to review the kernel thermal rules.
>
> **Table: Temperature for hardware and software throttling for CQ2390**
>
> | Mitigation Actions | Details |
> | - | - |
> | Software throttling | GPU: 115°C - Frequency throttling |
> | Hardware throttling | CPU: IL: 117°C, OL: 115°C - Frequency throttling |
> | BCL | |
> | ThermalD | [Learn more](https://dragonwingdocs.qualcomm.com/archives/2.0/System/Power/thermalD.md) |
> | Software shutdown | 115°C - Device shutdown |
> | Hardware shutdown | 120°C - Device shutdown |
>
> **Table: Available CPU cooling devices to user space for CQ2390**
>
> | **Cooling devices** | **Description** |
> | - | - |
> | `cpufreq-cpu\<x\>` | Cooling devices that are used to limit the maximum operating frequency of the CPU to control CPU temperature. <ul><li>`X` – Cluster CPU number</li><li>`cpufreq-cpu0` – Cluster0</li><li>`cpufreq-cpu3` – Cluster1</li></ul> |

***

## Next Steps

* [Thermal Architecture Details](https://dragonwingdocs.qualcomm.com/archives/2.0/System/Power/thermal-architecture.md)
* [Configure a Thermal Zone](https://dragonwingdocs.qualcomm.com/archives/2.0/System/Power/configure-a-thermal-zone.md)
* [Control Heat Dissipation](https://dragonwingdocs.qualcomm.com/archives/2.0/System/Power/control-heat-dissipation-with-cooling-devices.md)