> ## Documentation Index
> Fetch the complete documentation index at: https://dragonwingdocs.qualcomm.com/llms.txt
> Use this file to discover all available pages before exploring further.

# Multi-Camera Offline IFE

> Enable concurrent streaming from up to 4 bayer cameras on a single IFE hardware instance by routing frames through DDR using the Offline IFE feature on IQ-9075-EVK and IQ-8275-EVK.

IQ-9075-EVK
IQ-8275-EVK
Stable

> [card] 4
>
> Cameras (IQ-9075-EVK)

> [card] 3
>
> Cameras (IQ-8275-EVK)

> [card] 1
>
> IFE Hardware Used

> [card] SFE
>
> Bus Fetch Engine

> [!NOTE]
>
> **Platform Scope:**\\
>
> This feature is applicable for **IQ-9075-EVK** and **IQ-8275-EVK** only.\\
>
> Both platforms have two IFEs that natively support real-time de-bayering of bayer camera images.

***

## 01 · What Is It?

The Offline IFE feature allows a single IFE hardware instance to process bayer images from **multiple cameras** by running in **offline mode**. Instead of real-time de-bayering, frames are first stored in DDR via IFE-Lite's RDI port, then fetched by the IFE using the SFE Lite bus engine for bayer-to-YUV conversion.

```
Real-Time Path:    Sensor → IFE-Lite (RDI) → DDR
Offline Path:      DDR → SFE Lite (Fetch) → IFE Offline → YUV Output
```

![](https://mintcdn.com/qualcomm-prod/GT2F418k3S6CrAzc/archives/2.0/Technologies/Camera/images/multi_camera_offline_IFE.png?fit=max\&auto=format\&n=GT2F418k3S6CrAzc\&q=85\&s=5702838d2ae13cd7e68c839e8611a880)

***

## 02 · What Does It Control?

Controls how many concurrent bayer cameras can stream simultaneously by reusing a single IFE in offline mode rather than requiring dedicated IFE instances per camera.

| Capability | Without Offline IFE | With Offline IFE |
| - | - | - |
| Concurrent bayer cameras | 2 cameras max | 4 cameras (IQ-9075-EVK) |
| IFE instances required | 1 per 2 cameras | 1 shared (offline) |
| Frame routing | Direct sensor → IFE | Sensor → IFE-Lite → DDR → IFE |
| SFE Lite usage | Not used | Used as bus fetch engine |
| IQ-8275-EVK camera count | 2 cameras max | 3 cameras |

***

## 03 · Feature Validation

> [!NOTE]
>
> Connect to the device console using SSH. See [How To SSH?](https://dragonwingdocs.qualcomm.com/Linux/devices/iq9075-evk/set-up-the-device.md#connect-over-ssh) for instructions.

### Platform Reference Configurations

Ensure you have connected one of the following camera configurations:

* **IQ-9075-EVK**: Four OV9282 MIPI cameras connected to four MIPI CSI slots (0, 1, 2, and 3).
* **IQ-8275-EVK**: Three OV9282 MIPI cameras connected to three MIPI CSI slots (0, 1, and 2).

> [card] IQ-9075-EVK Config
>
> | Key | Value |
> | - | - |
> | Camera count | 4 |
> | Sensor | OV9282 MIPI |
> | MIPI CSI slots | 0, 1, 2, 3 |
> | Format | NV12 1280×720 |

> [card] IQ-8275-EVK Config
>
> | Key | Value |
> | - | - |
> | Camera count | 3 |
> | Sensor | OV9282 MIPI |
> | MIPI CSI slots | 0, 1, 2 |
> | Format | NV12 1280×720 |

**1. Collect user log**

```text Collect User Log theme={null}
# On device console
journalctl -f > /opt/user_log.txt
```

**2. Collect kernel log**

```text Collect Kernel Log theme={null}
dmesg -w  > /opt/kernel_log.txt
```

**3. Run GStreamer pipeline with multicamera-hint=true**

Run the following for **each camera** (change `camera=0` to `1`, `2`, `3` accordingly):

```bash GStreamer Pipeline theme={null}
gst-launch-1.0 -e qtiqmmfsrc name=camsrc camera=0 multicamera-hint=true ! \
video/x-raw,format=NV12,width=1280,height=720,framerate=30/1,\
interlace-mode=progressive,colorimetry=bt601 ! v4l2h264enc \
capture-io-mode=4 output-io-mode=5 extra-controls="controls,video_bitrate=6000000,\
video_bitrate_mode=0;" ! h264parse ! mp4mux ! filesink location=/opt/mux_avc.mp4
```

> [!WARNING]
>
> **Repeat for each camera**\
> Run similarly for `camera=1`, `camera=2`, and `camera=3` (IQ-9075-EVK) or up to `camera=2` (IQ-8275-EVK) with `multicamera-hint=true` on each.

**4. Verify log output**

After running the pipeline, confirm the feature is active by checking these exact log entries:

**User log — CamX pipeline status:**

```text User Log Trace theme={null}
CamX: [CORE_CFG]3509 3556 [CORE   ] camxpipeline.h:4222 SetPipelineStatus() RealTimeFeatureZSLPreviewRawOfflineIFE_0_cam_0 status is now PipelineStatus::STREAM_ON
```

**Kernel log — IFE acquisition confirmation:**

```text Kernel Log Trace theme={null}
CAM_INFO: CAM-ISP: cam_ife_hw_mgr_print_acquire_info: 1733: 0:4:11.835 Acquired Single IFE[0] SFE[0] OFFLINE: Y with [9 pix] [0 pd] [0 rdi] ports for ctx:1
```

> [!TIP]
>
> `OFFLINE: Y` in the kernel log confirms the IFE is running in offline mode. `STREAM_ON` in the user log confirms the CamX pipeline is live.

***

## 🛠️ Troubleshooting

| Issue | Cause | Fix |
| - | - | - |
| Only 2 cameras stream; 3rd/4th dropped | `multicamera-hint=true` not set on all streams | Ensure every `gst-launch` call includes `multicamera-hint=true` |
| `OFFLINE: N` in kernel log | Offline IFE not acquired — possible resource conflict | Restart camera service; verify no other pipeline is holding IFE |
| Pipeline stalls or drops frames | DDR bandwidth saturation at 4-camera load | Reduce framerate to 24fps or lower resolution to 720p |